Broadband testing platform for use in central
offices, remote nodes, co-location sites, and next
generation access nodes. Accurate fast, testing for
reactive or preventive maintenance and service assurance
for adsl, adsl2+, carrier ethernet, and iptv services.
Broadband test platform for use in today´s broadband accss network that performs complete
electrical tests and broadband frequency sweeps for service assrance pre-qualification.
With our remote access software can be programmed to perform automated preventive testing
capabilities to repair. The siplex pro broadband test platform is the most flexible and
accurate test platform on the market today.
 |
 |
Simulation of line. |
 |
Simulation of capacitive and resistive load. |
 |
Connection to ground of any pair (A-B). |
 |
Connection to battery in any pair (A-B). |
 |
Detection of Terminal impedance of the pair (capacitance and REN). |
 |
Generator of siren tone towards the client. |
 |
Manual tests by clip in the MDF/DG. |
 |
Configuration of failure code. |
 |
Thresholds of electrical tests configurable by the user. |
 |
Tests towards the central of: Voltages, power and tone frequency. |
 |
Generation of tones compatible with receivers of the market. |
 |
Measurement of generation of DTMF tones. |
 |
RID Compatibility. |
 |
VF Measurements. |
 |
ATU-C, ATU-R Tests (optional). |
 |
Ping Tests (Optional). |
 |
Connectivity through external matrices for data nodes (optional). |
 |
| SIPLEX PRO BASIC TESTS |
| Voltage Measurements |
 |
Detection of dangerous voltage |
 |
AC Voltage and the frequency: A-B, A-T, B-T, 0 to 300 Volts ± 2%. |
 |
DC Voltage: A-B, A-T, B-T, 400 Volts ± 2%. |
| Resistance Measurements |
 |
Insulation Resistance: A - B, A-T, B-T, 0 to 1 GOhm. |
| Capacitance Measurement |
 |
Capacitance: A-B, A-T, B-T, 1 nF to 10 μF ± 2%. Of line |
 |
Capacitance: A-B, A-T, B-T, 1 nF to 10 μF ± 2%. Terminal Impedance |
 |
Capacitive balance: A-T, B-T, 0 to 100% ± 2%. |
 |
Distance: A-B, by capacitance up to 7000 meters ± 5%. |
| Current Measurement |
 |
RMS AC lnduced current and the frequency: A-B, up to 110 mA ± 2%. |
 |
DC Current: A-B, up to 110 mA ± 2%. |
SIPLEX PRO EXTENDED TESTS.
Prequalification for ADSL, ADSL2, ADSL2+ and SHDSL services, from a single end. This test allows to estimate the velocity of a pair to support each service individually, giving the UP/DOWN-STREAM velocity projected in this pair, from 4,3 khz to the respective bandwidth, showing the following information for each test:
| |
 |
Diverse norms configurable by the user |
 |
It measures attenuation in each bandwidth |
 |
It measures background noise in each bandwidth |
 |
It reports the bits by carrier. |
 |
RMS Value of the background noise. |
 |
Detection of possible noise spectrum. |
 |
Distance of the pair. |
 |
UPSTREAM and DOWNSTREAM velocity. |
The tests in broadband will depend on the central and network protections.
| Loading coils |
 |
Detection of up to 6 loading coils. |
| Distance Measurements (TDR). |
 |
Distance to event: 0 to 5000 meters ± 2% |
 |
Analysis of derivations. |
| PSD Broadband Tests. |
 |
Spectral density of power in broadband from 2.16 KHz to 2 MHz, from 30 dBm to -120 dBm |
 |
E, F and G IEEE-743/1995 Filters for ISDN, HDSL, ADSL |
Frequency response of Pair.
|
 |
The frequency response is measured up to 2 MHz from 0 to -90 dB. |
| Test of Longitudinal Balance. |
 |
From 26 KHz to 1104 KHz, 0 to 80 dB ± 2. |
Measurement of Impulsive Noise |
 |
From 0 to -90 dBm, maximum counter of 65000, duration from 1 minute to 24 hours |
| Physical Characteristics |
 |
Environmental temperature: -10°C to +60°C |
 |
Temperature of internal operation: 0°C to 50°C. |
 |
Relative humidity: up to 95%, non-condensed |
 |
Electrical supply of -48 ± 6 DC Volts |
| |
|
|