A portable field unit that interfaces with the network at the F-1 or F-2 (mdf/field cabinets). the siplex solution allows the collection of test information and pair
information that permits the pre-qualifiation of broadband services such xdsl or
iptv, metro ethernet, and cellular backhaul while also verifing the number asscolated with each pair to create an accurate outside plant database the F-1 and F-2 database is
independently tested by means of a simulaneous connection via front tap shoes that permit the testing of 100 pairs per siplex mat units can be connected in series to permit the
testing of N(100) number of cable pairs.
 |
| |
|
| |
|
 |
Diagnosis of quality of the pair for services of broadband and voice |
 |
Simulation of line. |
 |
Simulation of capacitive and resistive loads. |
 |
Tone generation (compatible with receivers of the market). |
 |
Loudspeaker with amplification |
 |
Online presentation of the inventoried telephone number. |
 |
Connection to the monitoring point of a pair or manual test to any pair of SIPLEX MAT. |
 |
Open and friendly software in a graphical environment of multitasking administration. |
 |
It makes possible to consult information, to verify results, to request support, to execute tests as simultaneous and independent tasks. |
 |
The equipment will notify by audio alarms when finishing processes under execution. |
 |
Graphical display of the status of each stripe/block, with a color convention that allows to recognize the status of each pair: working, vacant, damaged, under special service, etc. |
 |
It allows to configure the diagnosis codes of each pair, according to the references used by the company.
|
| The equipment associates each pair with: city, central, primary network, secondary network, cabinet or district, cable, type of reglet in the cabinet or distributor, pair number, subscriber number associated to the electrical test or prequalification for broadband |
| |
| |
 |
| |
| SIPLEX VER BASIC TESTS |
| Voltage Measurements |
 |
Detection of dangerous voltage |
 |
AC Voltage and the frequency: A-B, A-T, B-T, 0 to 250 Volts ± 2%. |
 |
DC Voltage: A-B, A-T, B-T, 400 Volts ± 2%. |
| |
| |
| Resistance Measurements |
 |
Insulation Resistance: A- B, A-T, B-T, 0 to 1 GOhm. |
| |
| |
| Capacitance Measurement |
 |
Capacitance: A-B, A-T, B-T, 1 nF to 10 μF ± 2%. |
 |
Capacitive balance: A-T, B-T, 0 to 100% ± 2%. |
 |
Distance: A-B, by capacitance up to 7000 meters ± 5%. |
| |
| |
| Current Measurement |
 |
RMS AC Induced current and the frequency: A-B, up to 77 mA ± 2%. |
 |
DC Current: A-B, up to 110 mA ± 2%. |
| |
| |
| Prequalification for ADSL and G.SHDSL services. |
| This test allows to estimate the velocity when joining both services, giving the UP/DOWN-STREAM velocity projected in such pair, of 4,3 KHz to 1104 KHz, under one of the norms: |
 |
ANSI/POTS |
 |
ITU-T, A/POTS Annex |
 |
ETSI/POTS |
 |
G-LITE/POTS |
 |
ITU-T, B/ISDN Annex |
 |
ETSI/ISDN |
| The broadband tests will depend on the central and network protections. |
| |
| |
| MANUAL TESTS |
| |
| Distance Measurements (TDR). |
 |
Distance to event: 0 to 5000 meters ± 2% |
 |
Analysis of derivations. |
| |
| PSD Broadband Tests. |
 |
Spectral density of power in broadband from 2,16 KHz to 2 MHz, of 30 dBm to -120 dBm. |
 |
E, F and G IEEE-743/1995 Filters for ISDN, HDSL, ADSL, ADSL2+. |
| |
| Frequency response of the Pair |
 |
The frequency response is measured up to 2 MHz from 0 to -90 dB. |
| |
| Test of Longitudinal Balance |
 |
From 26 KHz up to 1104 KHz, 0 to 80 dB ± 2. |
| |
| Power |
 |
Connection for external AC supply (110 Volts). |
 |
Internal battery with 4 hours of autonomy. |
 |
External battery with extended autonomy (Optional). |
 |
Adapter for connection to the cigarette lighter of the automobile (12 Volts). |
| |
| Environmental Characteristics |
 |
Environmental temperature: -10°C to +60°C. |
 |
Temperature of internal operation: 0°C to 50°C. |
 |
Relative humidity: up to 95%, non-condensed. |
|